Ecler MPA 6-80R User Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
10
3.6. Output connections
The OUTPUTS section at the rear panel has screwable terminals (43, 44, 45, 46, 47, 48), one for
each amplifier.
The attenuation controls and the output configurations are described later in paragraph 3.7.
The cable which connects the speakers to the amplifier should be high quality and as short and
thick as possible. This is important when covering long distances; For up to 10m we recommend a cable
section not smaller than 2.5mm². For longer distances we recommend 4mm².
ALWAYS USE CLASS 2 WIRING FOR THE SPEAKERS CONNECTION.
Remember that the minimum load impedance for stereo or mono amplifiers is 4. In bridged
mode the impedance must be not less than 8. For a reliable operation under any circumstance connect
lower load impedances than just specified.
Attention: use only the indicated terminals when using the amplifiers in bridge mode.
Connect the terminal blocks securely, removing the cable cover 5÷7mm from the end.
CAUTION: The output connectors are HAZARDOUS LIVE.
Be sure to avoid leaving wires exposed. This can cause
short-circuit and risk of electric shock.
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 59 60

Comments to this Manuals

No comments